Tank overflowing or backing up? Call now 01432 667324

Septic tank size and emptying calculator for Herefordshire homes

Check whether your septic tank is big enough for your household and get a rough idea of how often it should be emptied.

An estimate and a guide to the rules, not legal advice.

How the calculator works

First, it checks your tank size. The long-standing sizing formula from BS 6297:1983, the British Standard code of practice for small sewage treatment works, gives a minimum capacity for a septic tank emptied at least every 12 months:

C = 180P + 2,000

where C is the capacity in litres and P is the number of people the tank serves, with a minimum of 4. So the smallest tank for any house is 2,720 litres, and six people need at least 3,080 litres. Building regulations guidance (Approved Document H) gives almost the same answer: 2,700 litres for up to four people, plus 180 litres for each extra person. If your tank is below the minimum for your household, the calculator flags it.

Second, it estimates an emptying interval. Published figures for how fast sludge and scum build up vary widely, from about 40 to well over 150 litres per person per year; the calculator uses 80 as a rough planning figure. A common rule of thumb is to empty before they fill about a third of the working volume, because beyond that solids wash through to the drainage field. The calculator works out how long that takes.

It then compares that with the Environment Agency's general binding rules, which say you "should do this at least once a year or in line with the manufacturer's instructions". You get whichever is shorter, which for most Herefordshire households means once a year.

What the answer does not know

Real tanks fill faster when:

  • The house is a holiday let or has lots of visitors. A cottage near Ross-on-Wye that sleeps eight in summer needs an eight-person answer. Use the peak number.
  • There is a waste disposal unit in the kitchen sink.
  • A water softener discharges to the tank. Brine adds volume and can upset the bacteria.
  • Rainwater gets in. Connected downpipes, broken lids or cracked walls let rain and groundwater in, common on older tanks in low ground by the Lugg and the Wye. See heavy rain and overflowing tanks.

Old brick and concrete tanks on farmhouses often have no marked capacity; whoever empties the tank can usually tell you roughly how much came out.

Treatment plants follow the manufacturer's schedule; for sealed tanks see cesspit emptying. Read how often to empty a septic tank and the signs your septic tank is full. Typical prices are on the emptying cost page.

Questions

What size septic tank do I need for a four-bedroom house?

Size is based on people rather than bedrooms. A four-bedroom house is often assumed to house six, which under BS 6297 needs at least 3,080 litres. If more people regularly stay, size for them.

My tank is smaller than the minimum. Is that illegal?

Not in itself. The rules expect a system to meet the British Standard in force when it was installed and to have enough capacity for the load. An undersized tank needs emptying more often, and a septic tank survey is worth having if there are problems.

Can I leave it longer than a year if the calculator says so?

The general binding rules say at least once a year, or in line with the manufacturer's instructions. Unless your tank's manufacturer states a longer interval, plan on yearly septic tank emptying.

Get a septic tank quote

Emptying, repairs, treatment plants and surveys across Herefordshire. Quotes are free.