Tank overflowing or backing up? Call now 01432 667324

Heavy rain and overflowing septic tanks in Herefordshire

Floods and high water tables are a fact of life along the Wye, Lugg, Frome and Arrow. Here's how they affect a septic tank and what to do.

Updated 29 September 2026 · facts checked against the official sources linked below

Waterlogged grassland with standing water

Herefordshire floods regularly. The Wye comes over its banks at Hereford and Ross-on-Wye, the Lugg meadows east of the city are often under water in winter, and the Frome and Arrow valleys fill quickly after heavy rain on the hills. For off-mains properties, it isn't only surface flooding that causes trouble. A rising water table can stop a septic tank working weeks before any water appears on the lawn.

Why rain affects a septic tank

A septic tank only works if the liquid leaving it has somewhere to go. In a drainage field, that means soil with enough air in it to absorb effluent. When the ground is saturated, the drainage field stops taking water, the level in the tank rises, and the system backs up.

Three things tend to happen in wet weather:

  • High water table. Low-lying land along the rivers, including Hampton Bishop, Mordiford, Wilton near Ross and the lower Lugg around Bodenham, can see groundwater close to the surface for long spells in winter. Drainage fields laid in that ground struggle every winter.
  • Groundwater ingress. Older brick and concrete tanks often have cracked walls or open joints. When groundwater rises above them, it runs straight in and fills the tank with clean water, pushing sludge out towards the drainage field.
  • Surface water. Downpipes, gully drains or land drains connected to the septic tank, which is common on older farm sites, can overwhelm it in a single storm. Rainwater should never go into a septic tank.

On Herefordshire's heavy clay, even ground well away from the rivers can stay waterlogged for weeks, and the problems look much the same.

During a flood

  • Use as little water as you can. Every flush and wash adds to a system that can't discharge.
  • Don't have the tank pumped out while the ground is flooded unless you've been advised to. An empty tank in saturated ground can be forced upwards by groundwater pressure, and plastic and fibreglass tanks are especially at risk of lifting or collapsing. It will also refill with floodwater almost immediately.
  • Switch off power to a treatment plant if its control panel, blower or pump is under water or about to be, and only if it's safe to reach the switch.
  • Keep clear of floodwater around the tank and drainage field. It's likely to be contaminated.
  • Don't lift the lids to look. Covers can be displaced by floodwater and an open chamber is a serious hazard when you can't see it.

If sewage is backing into the house, go to emergency septic tank emptying or call 01432 667324.

After the water goes down

  1. Wait until the ground has drained before using the system normally. Build up slowly.
  2. Check the lids and chamber tops are still in place and undamaged, and that the tank hasn't shifted. Uneven ground or a lid sitting at an angle can mean it has moved.
  3. Have the tank emptied once the water table has dropped. Floodwater carries silt and debris in, and pushes sludge out. On the Wye and Lugg meadows, septic tank emptying around Hereford covers flood-silted tanks in more detail.
  4. For a treatment plant, don't switch it back on until the electrics have been checked. Blowers and control panels are not designed to be submerged.
  5. Watch the drainage field for a few weeks. Soft ground, smells or slow drains after everything else has dried out suggest it has been damaged. The drainage field failure guide explains what to look for.

Reducing the risk next time

If your system struggles every winter, the ground conditions are the real issue, and emptying more often only treats the symptom. Options worth discussing include:

  • disconnecting any rainwater or land drains from the tank
  • sealing or relining a leaking tank, or replacing it with a sealed modern one
  • rebuilding or relocating the drainage field on higher, better-draining ground, sometimes as a raised mound
  • replacing the septic tank with a treatment plant, which may give different options for where the treated water goes

Under the general binding rules, drainage mounds and engineered ground can't be used in a floodplain, and a new drainage field or treatment plant needs Building Regulations approval and must either meet the rules or be covered by an environmental permit. See the general binding rules page.

Questions

Why does my tank overflow every winter but work fine in summer?

Almost certainly a seasonal high water table or surface water getting in. The drainage field can't discharge into saturated ground, and a leaking tank may be taking in groundwater too.

Should I get the tank emptied during a flood?

Not unless you've been advised to by someone who has seen the site. Pumping out a tank surrounded by saturated ground can cause it to lift or collapse, and it will refill with floodwater straight away.

Does my home insurance cover a flooded septic tank?

It depends on the policy. Some cover damage to underground services; many exclude gradual deterioration. Check your policy wording and keep records of the damage.

Can floodwater from my tank reach the river?

Yes, which is why it matters so much here. The Wye and Lugg are protected sites with phosphate problems. See Wye and Lugg phosphate.

Get a septic tank quote