A septic tank does the settling. The drainage field, sometimes loosely called a soakaway or leach field, does the rest: perforated pipes laid in gravel-filled trenches let the liquid from the tank seep into the soil, where it's treated by the ground itself. When the field stops soaking away, the whole system backs up.
In Herefordshire, drainage fields fail more often than in many counties, and the reasons are mostly underground.
Why they fail here
Clay and marl
Much of the county sits on the red mudstones and marls of the Old Red Sandstone, weathering to heavy, slowly permeable clay soils. They're excellent for grass, cider apples and hops, and poor at absorbing effluent. A drainage field on this ground may cope when first laid, then gradually seal as the trench walls smear and clog.
A biological mat
Every drainage field grows a thin layer of bacteria and organic matter where effluent meets soil. On free-draining ground it stays in balance. On clay, or when the field is overloaded, the mat thickens until almost nothing passes through.
Solids carried over from the tank
A tank that's overdue for emptying, or has a missing or broken outlet baffle, sends sludge and scum into the pipes. Once solids reach the gravel, they don't come back out. This is the most avoidable cause of failure, and one reason annual septic tank emptying matters.
Compaction
Cars parked on the field, a tractor driven across it, livestock poaching wet ground, or a garden building put on top. Compacted soil loses the air spaces it needs.
Roots
Willows, poplars and leylandii near the trenches send roots into the pipes. Older farmhouse fields often have hedgerow trees along one side.
High water tables
Along the Wye, Lugg, Frome, Arrow and Monnow, groundwater can sit close to the surface for much of the winter. A field in saturated ground can't discharge anything, however well it was built. See heavy rain and overflowing tanks.
Age and design
Many older Herefordshire properties don't have a true drainage field at all: just a single soakaway pit, a rubble-filled hole, or a pipe running to a ditch. Those were acceptable once. They rarely meet today's standards, and a pipe straight to a ditch or stream from a septic tank isn't allowed under the general binding rules. See discharge to a ditch or stream.
The signs
- Lush, bright green strips of grass along the line of the trenches.
- Soft, spongy or waterlogged ground over the field, even in dry weather.
- Sewage smells in the garden.
- Slow drains and gurgling, even soon after the tank has been emptied.
- The liquid in the tank sitting above the outlet pipe.
- Effluent surfacing or running into a ditch.
How a failing field is checked
Checks usually move from simple to detailed:
- Tank inspection. The level in the tank, the condition of the outlet and baffle, and whether the tank refills quickly from the field side after emptying.
- Locating the field. Plenty of homeowners don't know where theirs is. Old plans, distribution chambers and the pattern of grass growth all help.
- Distribution and inspection chambers. Lifting these shows whether effluent is ponding in the pipes.
- CCTV survey of the pipes to spot collapses, root ingress and silt.
- Trial holes alongside the trenches to see the soil, the gravel condition and the water table.
- Percolation test. Holes are dug, filled with water and timed as they drain, to show whether the ground can take a drainage field at all. Building Regulations guidance sets how this is done and what result is acceptable.
The fixes
Depending on what's found:
- Clearing and jetting the pipes, where the problem is silt or roots rather than the soil.
- Resting the field by switching to an alternate section, where one exists.
- Repairing the tank outlet or baffle to stop solids carrying over.
- Extending the field with new trenches in fresh ground.
- Replacing the field entirely, sometimes elsewhere on the plot or as a raised mound where the water table is high (mounds can't go in a floodplain under the general binding rules). Typical Herefordshire range £3,000–£8,000.
- Upgrading to a treatment plant. Cleaner effluent is gentler on the soil, and in some cases it opens up other options for where the treated water goes. It's also the direction of travel in the Wye and Lugg catchments.
The drainage fields page covers design, percolation testing and replacement in more detail.
Questions
Can a failed drainage field recover on its own?
Sometimes partly, if it's rested and the cause is removed. On heavy clay a badly clogged field rarely recovers fully.
Will emptying the tank fix it?
It gives temporary relief because the tank has space again. If the field isn't soaking away, the symptoms come back within weeks.
How long should a drainage field last?
A well-designed field in suitable ground, with a tank emptied every year, can last for decades. On poor clay, or with a neglected tank, it can fail in a few years.
Do I need permission to replace a drainage field?
A new drainage field normally needs Building Regulations approval from Herefordshire Council, and the discharge must meet the general binding rules or be covered by a permit.