A sewage treatment plant does what a septic tank does, then goes further. Air is pumped or drawn through the effluent so bacteria can break it down properly, and the water that leaves is much cleaner than septic tank effluent. That's why plants are the usual upgrade for a septic tank that discharges to a ditch, and why they come up so often in conversations about the Wye and Lugg.
Choosing one is less about the brand than about the right size, the right certification and a plant that suits the site.
Sizing: population equivalent
Plants are sized by population equivalent (PE), a measure of the load one person produces in a day. Sizing is based on the property's potential occupancy, usually worked out from the number of bedrooms, not how many people live there today. A three-bedroom cottage near Ledbury with two occupants still needs a plant sized for the house.
British Water's Flows and Loads guidance, which the general binding rules point to, sets a minimum of 5 PE for a single house with up to three bedrooms, plus one for each extra bedroom. Larger models cover bigger houses, several properties sharing one plant, or holiday lets. Undersizing is a common and expensive mistake, particularly for barn conversions and busy holiday lets.
Plants also have limits on intermittent use. Some cope better than others with a holiday let that sits empty for weeks, then takes eight guests. Ask the manufacturer directly.
Certification: EN 12566-3
New plants for up to 50 PE should be certified to BS EN 12566-3, the European standard for packaged domestic wastewater treatment plants. The general binding rules require new systems to meet the relevant British Standard. The certificate comes with test results for treatment performance, so you can compare plants on data rather than claims. Ask for them.
Brands you'll come across
These names turn up regularly in Herefordshire. Each offers a range of sizes and designs, and none is the right answer for every site.
- Klargester BioDisc (Kingspan). A long-established rotating disc design, driven by a small motor.
- Clearwater (Kingspan). A range of domestic and commercial plants.
- Vortex (WTE). Domestic plants using an aerated process, marketed as adjustable to the number of occupants.
- Marsh. Marsh Industries' Ensign range and others.
- Tricel. The Novo range is widely installed.
- WTE. Domestic treatment plants and larger systems.
Beyond the design, check that servicing and spare parts are easy to get locally, and whether whoever installs the plant is approved by the manufacturer, since this can affect the warranty.
Power use and noise
Most plants run all the time. Many use an air blower; rotating disc designs use a motor instead. A domestic plant typically draws somewhere in the region of tens of watts continuously, so running costs are modest but real. Compare manufacturers' published figures.
Blowers make a low hum. Where the plant sits relative to bedrooms, patios and neighbours matters, especially on tight village plots in places like Fownhope or Weobley. Some blowers can be housed in a separate kiosk away from the tank.
You'll also need a suitable power supply run to the plant, installed and certified by a qualified electrician, and an alarm that tells you when something stops.
Servicing costs
A treatment plant needs more looking after than a septic tank. Budget for:
- a service visit, usually yearly, to check the blower or motor, diffusers, pumps, alarm and effluent quality, roughly £150–£300 a year in Herefordshire
- desludging, typically once a year or as the manufacturer states
- replacement parts over time, such as blower diaphragms
The sewage treatment plant servicing page has more.
Phosphate and the Wye catchment
The River Wye and River Lugg are protected sites, the Lugg and stretches of the Wye are failing their phosphate targets, and Herefordshire Council's guidance recommends treatment plants over septic tanks where the aim is to cut nutrients. A standard plant removes more phosphorus than a septic tank, but not all of it. Some models offer enhanced phosphate removal, usually by chemical dosing, and some planning and permit situations in the catchment can set specific limits.
If phosphate matters for your project, particularly for new dwellings, conversions or discharges to a watercourse, look at each plant's certified phosphorus results and check what's required before you order. See Wye and Lugg phosphate.
Where the treated water goes
A plant still needs somewhere to discharge: a drainage field, or in some cases a watercourse, under the general binding rules or a permit. On Herefordshire clay, this often decides the design as much as the plant does. See discharge to a ditch or stream.
For options, sizes and what's involved on your site, see sewage treatment plants and sewage treatment plant installation. Supply and installation typically runs £6,000–£15,000 in Herefordshire.
Questions
Is a treatment plant always better than a septic tank?
It produces much cleaner effluent, but it costs more to run and needs power and servicing. Where a septic tank discharges to a sound drainage field in suitable ground, it may be perfectly adequate.
Can I reuse my old septic tank?
Sometimes an old tank can be converted, but in most cases it's emptied and decommissioned properly. See decommissioning a septic tank.
What happens in a power cut?
Treatment slows or stops until power returns. Short cuts rarely cause problems; the alarm should flag longer failures.
Do I need planning permission?
Usually not for a straight replacement, but Building Regulations approval is normally needed, and new development in the catchment may face phosphate conditions.